MIB Descriptions
C-14
7112-A2-GB20-10March 1998
Table C-7. DS1 Near End Group Configuration Table Objects (2 of 4)
Object, OID, Access Setting/ContentsDescription
dsx1LineCoding
(dsx1ConfigEntry 6)
1.3.6.1.2.1.1.10.18.6.1.6
read-write
Corresponds to the network
line coding configuration
option for the network
interface on the DSU/CSU.
Supports the following
values:
dsx1B8ZS(2) – Indicates
B8ZS line coding.
dsx1AMI(5) – Indicates
AMI line coding.
dsx1SendCode
(dsx1ConfigEntry 7)
1.3.6.1.2.1.1.10.18.6.1.7
read-write
Indicates the test
patterns/codes being sent
over the network interface.
Supports the following
values:
dsx1SendNoCode(1)
specifies that the interface
is sending normal or
looped data. Setting the
interface to this value
stops an active “send
pattern” test on the
interface.
dsx1SendLineCode(2)
specifies that the network
interface is sending a
Remote Loopback UP
code for 10 seconds.
dsx1SendResetCode(4)
specifies that the network
interface is sending a
Remote Loopback DOWN
code for 10 seconds.
dsx1SendQRS(5)
specifies that the network
interface is sending a
QRSS test pattern. The
pattern is sent until the test
is halted (i.e., setting to
dsx1SendNoCode).
dsx1SendOtherTestPatte
rn(8) – specifies that the
network interface is
sending a 1-in-8 test
pattern. The pattern is sent
until the test is halted (i.e.,
setting to
dsx1SendNoCode).
dsx1CircuitIdentifier
(dsx1ConfigEntry 8)
1.3.6.1.2.1.1.10.18.6.1.8
read-write
Contains the transmission
vendor’s circuit identifier,
for the purpose of
facilitating troubleshooting.
Applies to the T1 network
interface only.
A string of 0 to
255 characters.
Page view 115