Paradyne 7112 User Manual Page 130

  • Download
  • Add to my manuals
  • Print
  • Page
    / 156
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 129
MIB Descriptions
C-28
7112-A2-GB20-10March 1998
Table C-16. Generic Interface Test Table Objects (3 of 3)
Object Setting/ContentsDescription
ifExtnsTestResult
(ifExtnsTestEntry
5)
1.3.6.1.3.6.2.1.5
read-only
Contains the result of the
most recently requested
test.
Supports the following values:
none(1) – No test active.
inProgress(3) – Test is in
progress.
notSupported(4) – Requested
test is not supported.
unAbleToRun(5) – Test cannot
run due to the state of the unit.
ifExtnsTestCode
(ifExtnsTestEntry
6)
1.3.6.1.3.6.2.1.6
read-only
Contains a code providing
more specific information
about the test result.
Supports the following values:
none (wellKnownCodes 1) – No
further information is available.
Used for send pattern/code and
loopback tests.
inSyncNoBitErrors
(wellKnownCodes 2) – A monitor
pattern (QRSS or 511) test has
synchronized on the pattern and
has not detected any bit errors.
inSyncWithBitErrors
(wellKnownCodes 3) – A monitor
pattern (QRSS or 511) test has
synchronized on the pattern but
has detected any bit errors.
notInSync (wellKnownCodes 4)
– A monitor pattern (QRSS or 511)
test has not synchronized on the
requested pattern.
Page view 129