Page view 51
Monitoring the DSU/CSU
6-10
7112-A2-GB20-20
March 1998
Cross Connect Status
Use the Cross Connect Status screen to display the network interface time slots
assigned to the data port. These assignments are made using the Cross Connect
configuration option.
Use the following menu sequence to display network channel information.
Main Menu
Status
Cross Connect Status
The Cross Connect Status screen displays 24 two-field entries in three rows.
Together, each two-field entry defines the assignment for one network interface
time slot. The top field represents the time slot of the network interface. The
bottom field shows whether or not the time slot is assigned to the data port.
main/status/cross_connect PARADYNE
Device Name: Model: 7112
CROSS CONNECT STATUS
N01 N02 N03 N04 N05 N06 N07 N08
P P P P P P
N09 N10 N11 N12 N13 N14 N15 N16
N17 N18 N19 N20 N21 N22 N23 N24
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu M
ainMenu Exit
The following information is available for viewing.
The Network Time Slot Fields (top) . . .
Indicate the . . .
N01 to N24 Network Interface time slot (01 to 24).
The Cross Connect Status Field
(bottom) . . .
Indicates the time slot is . . .
blank Unassigned.
P Assigned to the data port.