Page view 97
Worksheets
B-2
7112-A2-GB20-10March 1998
Network Interface
Configuration Option Settings (default in Bold)
Primary Clock Source Network, Internal, Port
Line Framing Format ESF, D4
Line Coding Format B8ZS, AMI
Bit Stuffing 62411, Part68, Disable
Line Build Out (LBO) 0.0, –7.5, –15, –22.5
FDL Management Link Enable, Disable
FDL IP Address 000.000.000.000 – 255.255.255.255, clear
FDL Subnet Mask 000.000.000.000 – 255.255.255.255, clear
Class A defaults to 255.000.000.000
Class B defaults to 255.255.000.000
Class C defaults to 255.255.255.000
Network Initiated Line Loopback (LLB) Enable, Disable
Network Initiated Payload Loopback (PLB) Enable, Disable
ANSI Performance Report Messages Disable, Enable
Cross Identifier <Blank>
Cross Connect Assignments
Configuration Option Settings (default in Bold)
Assign By Block, ACAMI, Channel
Synchronous Data Port Assignments P(B)
The default is all DSOs assigned to the
data port
...
g
data port.
P(B)