Paradyne 7112 User Manual Page 105

  • Download
  • Add to my manuals
  • Print
  • Page
    / 156
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 104
MIB Descriptions
C-3
7112-A2-GB20-20
March 1998
Table C-1. System Group Objects (2 of 2)
Object, OID, Access Setting/ContentsDescription
sysServices
(system 7)
1.3.6.1.2.1.1.7
read-only
Functionality supported:
physical (1) – Layer 1
functionality for all
interfaces.
datalink/subnetwork (2)
– Layer 2 functionality
(SLIP/PPP) for all
management links.
internet (4) – Layer 3
functionality (IP) for all
management links.
end-to-end (8) – Layer 4
functionality (TCP/UDP)
for all management links.
Object is set to 1+2+4+8 (15).
Interfaces Group
The Interfaces Group as defined in RFC 1573 consists of an object indicating the
number of interfaces supported by the unit and an interface table containing an
entry for each interface. Since RFC 1573 is an SNMPv2 MIB, it is converted to
SNMPv1 for support by the unit. The following table provides clarification for
objects contained in the Interfaces group when it is not clear how the object
definition in RFC 1573 is supported by the unit.
Table C-2. Interfaces Group Objects (1 of 5)
Object
Description Setting/Contents
ifNumber
(interfaces 1)
1.3.6.1.2.1.2.1
Specifies the number
of interfaces for this
unit in the ifTable.
5
ifIndex
(ifEntry 1)
1.3.6.1.2.1.2.2.1.1
Provides the index to
the interface table
(ifTable) and to other
tables as well.
When an unsupported
index is entered (e.g.,
1 and 5), noSuchName
is returned.
Indexes and values:
1 – reserved
2 – Terminal port
3 – Ethernet port
4 – Network (T1) interface
5 – reserved
6 – User Data (DTE) port
8 – FDL
Page view 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 155 156

Comments to this Manuals