MIB Descriptions
C-20
7112-A2-GB20-10March 1998
DS1 Fractional Group
The DS1 Fractional Group consists of the DS1 fractional table. This table
(dsx1FracTable) is fully supported by the DSU/CSU and allows DS0 (time slots)
to be mapped between the network interface and the data port. The DSU/CSU
validates all channel configurations before applying them.
Ethernet-Like MIB – RFC 1643
The unit supports the Ethernet-Like MIB, RFC 1643 for all objects
except
:
dot3Tests
dot3ChipSets
dot3Errors
RS-232-Like MIB – RFC 1659
The unit supports RS-232-Like MIB, RFC 1659:
Number of RS-232-Like Ports Object.
General Port Table Objects, Table C-11.
Asynchronous Port Table Objects, Table C-12. Not supported for the User
Data port.
Synchronous Port Table Objects, Table C-13. Not supported for the Terminal
port.
Input Signal Table Objects, Table C-14. Not supported for the Terminal port.
Output Signal Table Objects, Table C-15. Not supported for the Terminal port.
Supported for the User Data port and the Terminal port. RFC 1659 is an SNMPv2
MIB, but is converted to an SNMPv1 MIB to support this unit. This MIB consists of
one object and five tables.
Number of RS-232-Like Ports Object
Supported as documented in the RFC.
General Port Table Objects
The General Port Table Objects contains configuration options for the
RS-232-Like interfaces. Clarification for objects contained in this table as it
applies to the unit is provided below.