Page view 32
Security
4-5
7112-A2-GB20-20
March 1998
Effective Access Level
The ATI effective access level (Table 4-1) is the more restrictive of:
Port/Session access level, or
The Access level associated with the Login ID.
For example, if a login ID is created with an Access Level 1 and the Terminal Port
is set for a Port Access Level of 2, the effective access level to the ATI is 2.
Table 4-1. Effective Access Levels
ATI Access to Menu Functions
Effective
Access Level 1
Effective
Access Level 2
Effective
Access Level 3
Status Full Access Full Access Read-Only
Test Full Access Full Access No Access
Configuration Full Access Read-Only Read-Only
Control Full Access No Access No Access
When user access to the ATI is attempted through the Terminal port or a Telnet
session, the ATI response is based on the Login Required option and the
availability of the ATI. Table 4-2 describes how the system responds to various
ATI access conditions.
Table 4-2. ATI Access Conditions (1 of 2)
If access to the ATI
is through the . . .
Then . . . What to do now?
Terminal port with
Security disabled with
the Login Required
option set to Disable
(See Table A-6)
The Main Menu screen
appears.
Select a menu option to begin your
session.
Terminal port with
Security enabled with
the Login Required
option set to Enable
(See Table A-6)
You are prompted for a
login ID and password.
If Invalid Password appears,
re-enter the password. After three
tries with an invalid password,
contact the system administrator.
(See Table A-6)
The Main Menu screen
appears if the login ID is
not configured yet.
Select a menu option to begin your
session.