B. SNMP MIBs and Traps, and RMON Alarm Defaults
B-22
September 2002 9128-A2-GB20-80
DLCI Alarm Defaults Paradyne Area
These alarms apply to all DLCIs on the network interface and can be created
during RMON initialization or when a DLCI is created. They are put into the
Paradyne-defined alarm area.
Table B-12. DLCI Alarm Defaults Paradyne Area (1 of 2)
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event
Type
Rising
Threshold
Default
Falling
Threshold
Default
DLCI Inactive
Seconds
D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciStsInactive-
Secs
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.2.
I
.
D
900 secs
(15 mins)
Rising 1 1
Missing
Latency
Responses
D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciMissedSLVs
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.23.
I
.
D
900 secs
(15 mins)
Rising 5 5
Rx FECNs D
MIB:
FR DTE MIB (RFC 2115)
Tag:
frCircuitReceivedFECNs
OID:
.1.3.6.1.2.1.10.32.2.1.
4.
I
.
D
60 secs
(1 min)
Rising 1 1
Rx BECNs D
MIB:
FR DTE MIB (RFC 2115)
Tag:
frCircuitReceivedBECNs
OID:
.1.3.6.1.2.1.10.32.2.1.
5.
I
.
D
60 secs
(1 min)
Rising 1 1
Congested
Seconds
D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciSts-
CongestedSecs
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.6.
I
.
D
60 secs
(1 min)
Rising 5 5
Frames
Dropped by
Network
D
MIB:
pdn_FrExt.mib (E)
Tag:
devFrExtDlciNetDropFr
OID:
.1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.20.
I
.
D
60 secs
(1 min)
Rising 1 1
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is
contained in the MIB.
A = Absolute. Indicates that the exact value for the item is contained in the MIB.
2
I
in the OID = Interface ID of the frame relay link.