8. Troubleshooting
9128-A2-GB20-80 September 2002
8-39
IP Ping Test Procedure 1
Procedure
To ping any far-end FrameSaver unit:
1. Select the IP Ping test.
Main Menu
Test
IP Ping
2. Enter the IP Address of the device the ping is being sent to, then select Start.
NOTE:
If the FrameSaver unit has just initialized, or the far-end unit has just
initialized, it may take about a minute for the units to learn the routes via
the proprietary RIP.
3. Verify the results of the IP Ping test.
While the test is running,
In Progress...
appears in the Status field.
When the test is finished,
Alive
should appear as the Status. If any
other message is displayed, additional testing is required.