Paradyne 9126-II User Manual Page 138

  • Download
  • Add to my manuals
  • Print
  • Page
    / 470
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 137
4. Configuration Options
4-94
September 2002 9128-A2-GB20-80
Configuring Ethernet Management
For the FrameSaver SLV 9126-II or 9128-II, select Ethernet Management from the
Management and Communication menu, or Ethernet Management Options
Screen from the Easy Install screen, to configure the Ethernet port (see
Table 4-23, Ethernet Management Options).
Main Menu
Configuration
Management and Communication
Ethernet Management
Main Menu
Easy Install
Ethernet Management Options Screen
Table 4-23. Ethernet Management Options (1 of 2)
Interface Status
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the Ethernet port is being used and can be configured.
Enable The port is active. It can receive Version 2 or IEEE 802.3 MAC frames and
transmit Version 2 MAC frames only. When the Ethernet port is enabled, the
Would you
like to set the Node's IP Destination to Ethernet?
prompt is displayed.
If you select Yes, the Default IP Destination (see Table 4-17, Node IP Options) is
automatically changed to Ethernet, so the Ethernet ports Default Gateway Address
is used for packets that do not have a route. This is required when the NMS is on a
different subnet than the unit.
If you select No, the COM port or a PVC will be used for packets without a route.
Disable The port is not active. When the port is disabled, the following will occur:
No alarms or traps configured for the port will be generated.
All port uses that refer to the Ethernet port, like the Default IP Destination and Initial
Route Destination, will be reset to their default values (see Table 4-17, Node IP
Options, and Table 4-22, SNMP Traps and Trap Dial-Out Options).
IP Address
Possible Settings: 001.000.000.000 223.255.255.255, Clear
Default Setting: Clear (000.000.000.000)
Specifies the IP address needed to access the Ethernet port.
001.000.000.000 223.255.255.255 Shows the IP address for the port, which can be
viewed or edited.
Clear Fills the IP address with zeros.
Subnet Mask
Possible Settings: 000.000.000.000 255.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the subnet mask associated with the IP address that is needed to access the
Ethernet port.
000.000.000.000 255.255.255.255 Set the Ethernet ports subnet mask. The range for
each byte is 000 to 255.
Clear Fills the subnet mask associated with the IP address with zeros.
Page view 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 469 470

Comments to this Manuals

No comments