Installation
2-73160-A2-GB22-10 December 1996
Installing the Single –ā48 Vdc Power Supply
To
install the 3160/3164 DSU/CSU using a single
source –
48 Vdc power supply, refer to Figure 2-8 and use
the following procedure.
T
o install the –
48 Vdc single source power supply
,
1.
Connect the black and red wires to the –48 Vdc
return source.
2. Connect the green wire to a suitable earth ground.
3.
Connect the orange and blue wires to the –
ā
48 Vdc
input source.
4. Cut the white wire off at the outer insulation.
5. Plug the power connector into the 3160/3164
DSU/CSU.
Figure 2-8. ā 48 Vdc Single Source Power Supply Pinouts