ACCULINK 316x DSU/CSU
2-6 December 1996 3160-A2-GB22-10
5. If you intend to manage the 3160/3164 DSU/CSU
with SNMP
, cable either the COM or MODEM
port (as appropriate for your configuration). Then,
configure the SNMP management link. See
Chapter 3, Operation,
and Appendix C,
Configuration Options,
for more information.
6. If you do not intend to use the DTE Drop/Insert
T1 port, disable it using the configuration
procedures in Chapter 3,
Operation
, and
Appendix C, Configuration Options
. (The default
setting for this port is Enabled.)
7. The Factory 1 configuration for ESF framing
format and B8ZS line coding format is the default
configuration and is appropriate for most
networks. If this configuration does not work for
you, try the Factory 2 configuration for D4
framing format and AMI line coding format. To
further customize configuration options, refer to
the
Configuring the DSU/CSU section in
Chapter 3, Operation
, and to Appendix C,
Configuration Options
.
8. Verify that the DSU/CSU is functional by
observing that the OK
and
NETWORK SIG
LEDs are lit.
9.
Configure the ports and channels you intend to use
and assign channels to the network interface. To
do so, refer to
Configuring the DSU/CSU
section
in Chapter 3, Operation
, and to Appendix C,
Configuration Options
.
Optional Power Selection
Using the optional dc power cable, the 3160/3164
DSU/CSU is capable of operating on either a +24 Vdc
power source, –
48 Vdc single source battery
, or –
48 Vdc
redundant source batteries (for power backup). T
o select
the power, choose one of the following power supply
types.
Installing the +24 Vdc Power Supply
To
install the 3160/3164 DSU/CSU using a +24 Vdc
power supply, refer to Figure 2-7 and use the following
procedure.
T
o install the +24 Vdc power supply
,
1. Connect the green wire to a suitable earth ground.
2. Connect the white wire to the +24 Vdc return.
3.
Connect the orange wire to the +24 Vdc source.
4. Cut the black, red and blue wires off at the outer
insulation.
5. Plug the power connector into the 3160/3164
DSU/CSU.
Figure 2-7. +24 Vdc Power Supply Pinouts