Operation
3-693160-A2-GB22-10 December 1996
Deactivating the Alarm Relay
The Alarm Cut-off command forces a deactivation of
the alarm relay on the 3000 Series Carrier during an alarm
condition. Since this function only af
fects the 3000 Series
Carrier, it is only available for Model 3161 DSU/CSUs.
The alarm relay function must first be enabled by the
Alarm Relay configuration option (see
Appendix C,
Configuration Options
).
To deactivate the alarm relay,
1.
Press the
key from the top-level menu screen
to bring the Ctrl branch onto the front panel LCD.
F1
DS
U E
SF
Stat Test Cnfig
F2
F3
2. Press F3 to select Ctrl from the top-level menu
screen.
F1
DS
U E
SF
Test Cnfig Ctrl
F2
F3
3. From
the Control screen, press F1 to select ACO.
F1
Control:
ACO Rel LED
F2
F3
4.
The Command Complete screen appears.
F1
Alarm Cut-Off:
Command Complete
F2
F3
Starting Front Panel
Emulation
The front panel emulation function enables you to
display the front panel of a specified near-end or far-end
316x DSU/CSU on a PC. If the DSU/CSU selected is not
locally attached to the PC, you must first dial to the
remote DSU/CSU before starting front panel emulation.
To start front panel emulation,
1. From the PC, open Program Manager from
Windows.
2. The Front Panel window opens.
NOTE
The modem attached to the PC
must support AT commands for
the Front Panel Emulation
software to successfully place the
call.