ACCULINK 316x DSU/CSU
D-12 December 1996 3160-A2-GB22-10
V.35 Port Interface Connector
The
V
.35 Port Interface connector information is
shown in Table D-9 and Figure D-8.
Table D-9
V.35 Port Interface Connectors
Signal
CCITT
Number
Direction Pin
Shield A
Signal Common 102 B
Transmitted Data 103 To DCE P (A)
S (B)
Received Data 104 From DCE R (A)
T (B)
Request-to-Send 105 To DCE C
Clear-to-Send 106 From DCE D
Data Channel Received Line
Signal Detector
109 From DCE F
Data Set Ready 107 From DCE E
Data Terminal Ready
108/1, /2
To DCE H
Transmit Signal Element
Timing (DTE Source)
113 To DCE U (A)
W (B)
Transmit Signal Element
Timing (DCE Source)
114 From DCE Y (A)
AA (B)
Receiver Signal Element
Timing (DCE Source)
115 From DCE V (A)
X (B)
Local Loopback 141 To DCE L
Loopback/Maintenance 140 To DCE N
Test Indicator 142 From DCE NN