Operation
3-233160-A2-GB22-10 December 1996
To Copy to One or All Ports
To copy the configuration options to one or all ports,
1. Press F3 to select Cnfig from the top-level menu
screen.
F1
DS
U E
SF
Stat Test Cnfig
F2
F3
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
function key
. Use the scroll keys, if necessary
.
F1
Load from:
Activ Cust Fact1
F2
F3
3. Press F1 to select Edit.
F1
Choose Funct:
Edit Save
F2
F3
4. Press F2 to select Port.
F1
Edit:
DTE Port NET
F2
F3
5. From the Port Select screen, press F1 (Copy).
F1
Port
S
elect:
Copy Prt1 Prt2
F2
F3
6. Select the port from which you want to copy the
configuration options using the corresponding
Function key.
F1
Copy From:
Prt1 Prt2 Prt3
F2
F3
7. Select the port to which you want to copy the
configuration options using the corresponding
Function key. Or, press F1 (All) to choose to copy
to all ports.
F1
Copy To:
All Prt1 Prt2
F2
F3
Differences
Using the Async T
erminal: From the
main/configuration/edit/ports menu, select a port. The
subsequent screen appears with the
Copy From field
populated with the port selected on the ports menu. The
port description fields are populated with the port
information. Specify the port to be copied to in the Copy
To field or ALL for all ports. T
ab to and select
Copy on
the right of the screen.