Operation
3-293160-A2-GB22-10 December 1996
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
function key
. Use the scroll keys, if necessary
.
F1
Load from:
Activ Cust Fact1
F2
F3
3. Press F1 to select Edit.
F1
Choose Funct:
Edit Save
F2
F3
4. Press the key from the Edit screen to display
the SNMP selection.
F1
Edit:
DTE Port NET
F2
F3
5.
Press F3 to select SNMP
.
F1
Edit:
User Alarm SNMP
F2
F3
6. Press F1 to select Gen from the SNMP Config
screen.
F1
SNMP Config:
Gen Trap
F2
F3
7. Press the F1 (Next) key until the Modem Link
configuration option appears.
F1
System Name:
Next Edit Clear
F2
F3
8. Press F2 (PPP) or F3 (SLIP).
F1
Modem Link:
Next PPP SLIP
F2
F3
Differences
Using the Async T
erminal: To set the Link
Layer Protocol, select Modem & Communication Port
Options from the main/configuration/edit/snmp menu.
(See Figure 3-22 for an example of the screen that
appears.)
Specifying the Community Name(s) and
Access Type(s)
You have the capability of specifying up to two
community names (community name 1 and community
name 2) to be used by external SNMP managers when
trying to access objects in the DSU/CSU’
s MIB. Once you
specify the community name(s), you must then specify the
type of access to the MIB that SNMP managers in the
community are permitted to have.
T
o specify the community name 1 and its access type,
1. Press F3 to select Cnfig from the top-level menu
screen.
F1
DS
U E
SF
Stat Test Cnfig
F2