Paradyne 9820 User Manual Page 193

  • Download
  • Add to my manuals
  • Print
  • Page
    / 281
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 192
Setting Up NetScout Manager Plus for FrameSaver Devices
10-15
9820-A2-GB20-20
June 2000
Installing the User-Defined History Files
Once the user-defined history files have been created, the files need to be
installed. History files are installed from the command-line prompt in NetScout
Manager Plus. Should the FrameSaver unit be reset, these files will need to be
reinstalled. The command used to install a new user history table is located in
$NSHOME/bin.
CAUTION:
Do not use user_history_table_1 or 2. UserHistory1 and UserHistory2
are the default user history files used to keep SLV data for reports.
Editing either of these files will destroy SLV reporting capability.
" Procedure
1. Type dvuhist -f
agentname user_history_table_number
config
number_of_buckets interval download_file
.udh to load user-defined history
files for the frame relay link.
Example:
dvuhist -f Dallas51 3 config 30 60 Dallas51k.udh
The interval must be entered in seconds.
2. Type dvuhist -f
agentname DLCI_number
user_history_table_number
config
number_of_buckets interval download_file
.udh to load user-defined
history files for a specific DLCI.
Example:
dvuhist -f “Dallas51 301” 3 config 30 60 Dallas301.udh
The same user history table number can be used for both the link and DLCI.
For these examples, user history table number 3 will appear as UserHistory3
on the History List.
See Step 5 in
Monitoring a DLCI’s History Data
to verify that the user-defined
history files have been loaded.
Refer to
Installing .UDH Files
in
Using Custom History
of the
NetScout Manager
Plus User Guide
for additional information.
Page view 192
1 2 ... 188 189 190 191 192 193 194 195 196 197 198 ... 280 281

Comments to this Manuals

No comments