Paradyne 9820 User Manual Page 163

  • Download
  • Add to my manuals
  • Print
  • Page
    / 281
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 162
Troubleshooting
8-9
9820-A2-GB20-20
June 2000
Table 8-1. Alarm Conditions (3 of 4)
Alarm Condition What To DoWhat It Indicates
LMI Down,
frame relay link
2
The Local Management
Interface is down for the
specified frame relay link.
For the network data port:
H If LMI was never up, verify
that the LMI Protocol setting
reflects the LMI type being
used.
H If LMI was never up:
Verify that the proper time
slots have been configured.
Verify that the LMI Protocol
setting reflects the LMI type
being used.
H Verify that Frame Relay
Performance Statistics show
LMI frames being transmitted.
If all of the above have been
verified and the physical link is
not in Alarm, contact your
network provider.
For user data port:
H Check that the DTE cable is
securely attached at both
ends.
H Verify that Transmit Clock
Source and Invert Transmit
Clock options are properly
configured.
H Verify that Frame Relay
Performance Statistics show
LMI frames being received. If
no frames are being received:
Check the attached device.
Verify that the LMI Protocol
setting reflects the LMI type
being used.
2
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network data port, Network 1.
– Port-1. The frame relay link associated with the user data port.
Page view 162
1 2 ... 158 159 160 161 162 163 164 165 166 167 168 ... 280 281

Comments to this Manuals