Paradyne 9820 User Manual Page 139

  • Download
  • Add to my manuals
  • Print
  • Page
    / 281
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 138
Monitoring
6-29
9820-A2-GB20-20
June 2000
Clearing Performance Statistics
Performance statistics counters can be reset to the baseline when using a directly
connected asynchronous terminal and your security Access Level is Level-1. This
feature is useful when troubleshooting problems.
Statistic counters are not actually cleared using this feature. True statistic counts
are always maintained so SLAs can be verified, and they can be viewed from an
SNMP NMS. However, since statistics can be cleared locally, the statistics viewed
via the menu-driven user interface may be different from those viewed from the
NMS.
" Procedure
To clear all statistics:
Performance Statistics
Clear All Statistics
" Procedure
To clear specific sets of statistics:
H Use the C
lrSLV&DLCIStats function key to reset the SLV and DLCI
performance statistic counters for the currently displayed DLCI from one of
the following screens:
Performance Statistics
Service Level Verification
Performance Statistics
DLCI
H Use the ClrLinkStats function key to reset the frame relay link performance
statistics.
Performance Statistics
Frame Relay
H Use the ClrStats function key to reset the Ethernet performance statistics.
Performance Statistics
Ethernet
Page view 138
1 2 ... 134 135 136 137 138 139 140 141 142 143 144 ... 280 281

Comments to this Manuals

No comments