Paradyne 9820 User Manual Page 128

  • Download
  • Add to my manuals
  • Print
  • Page
    / 281
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 127
Monitoring
6-18
9820-A2-GB20-20
June 2000
Health and Status Messages
The following table provides Health and Status messages that apply to the
FrameSaver unit.
Table 6-11. Health and Status Messages (1 of 2)
Message
What It Indicates
Auto-Configuration Active Auto-Configuration feature is active, which allows
automatic configuration and cross-connection of
DLCIs as they are reported by the network LMI.
Back-to-Back Mode Active The operating mode has been configured for
back-to-back operation (
Main Menu
Control
Change Operating Mode)
.
The FrameSaver unit can be connected to another
FrameSaver unit without a frame relay switch
between them.
This feature is useful for product demonstrations
or for a point-to-point configuration using a leased
line.
Backup Active (Model 9820-45M) A backup has been established
and data is flowing over an alternate DLCI.
Clock Out of Range at Network 1 A valid network data port rate cannot be detected
because the:
H Unit is trying to detect a valid port rate.
H Rate detected is greater than the highest port
rate supported by the unit.
FrameSaver SLV 9820 rates:
56/64 or 128 kbps in 56 or 64 kbps
increments
FrameSaver SLV 9820-2M rates:
64 – 2048 kbps in 64 kbps increments
FrameSaver SLV 9820-8M rates:
1024 – 8192 kbps in 8 kbps increments
FrameSaver SLV 9820-45M rates:
1024 – 44210 kbps in 8 kbps increments
CTS down to Port-1 Device (Models 9820, 9820-2M, 9820-8M) The user data
port CTS control lead on the FrameSaver unit is
off.
DLCI
nnnn
Down,
frame relay link
1,2
The DLCI for the specified frame relay link is down.
DTR Down from Port-1 Device The DTR control lead from the device connected to
the user data port is deasserted.
1
nnnn
indicates a DLCI number of 16 through 1007.
2
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
Page view 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 280 281

Comments to this Manuals

No comments